EUV Photon Shot Noise Calculator

At 13.5 nm each photon carries ~92 eV, so a printed feature is exposed by a countable, and randomly fluctuating, number of photons. Estimate that mean count and its Poisson shot-noise uncertainty from dose, wavelength, and feature area.

Illustrative educational model. Uses textbook Poisson photon statistics to build intuition. It is not calibrated to any specific resist, scanner, or process and must not be used as a fab-grade predictor.

How it works

A photon of wavelength λ carries energy E = hc / λ With hc = 1239.84 eV·nm, an EUV photon at 13.5 nm carries about 91.8 eV — roughly 14× the energy of a 193 nm DUV photon. Because the energy per photon is fixed, a given exposure dose corresponds to a specific number of photons per unit area:

photons / cm² = dose (mJ/cm²) × 10⁻³ / E(J)   →   photons / nm² = (photons / cm²) / 10¹⁴

At 30 mJ/cm² that is only ~20 photons per nm². Multiply by the feature area (and an optional absorbed fraction) to get the mean number of photons N that actually expose the feature. Photon arrivals are independent, so N follows Poisson statistics: the standard deviation is σ = √N and the relative shot noise is 1/√N. Halving the feature area or the dose raises that relative noise by √2 — which is why the smallest features at the lowest doses are where stochastic printing failures first appear.

What the model deliberately ignores

Further reading

The stochastic-defect literature around EUV is the place to calibrate intuition — for example the body of work by P. De Bisschop (imec) on stochastic printing failures, and resist-photon-statistics discussions from the SPIE Advanced Lithography community. Treat the numbers here as order-of-magnitude teaching values, not measured defectivity.

Constants & formulas used
h·c = 1239.841984 eV·nm  |  1 eV = 1.602176634×10⁻¹⁹ J  |  1 cm² = 10¹⁴ nm² E(λ) = 1239.842 / λ[nm] eV N = (dose[mJ/cm²] × 10⁻³ / E[J]) / 10¹⁴ × area[nm²] × absorbed_fraction σ = √N relative shot noise = 1 / √N

The "relative shot noise vs. feature size" chart sweeps feature area at the current dose/wavelength/absorption and plots 1/√N; the marker is your current feature. The 5% line is a rough visual cue for where photon-count fluctuations become a first-order concern, not a spec limit.